MIKROGEN Diagnostik has developed an extensive portfolio of PCR kits.
ampliCube
ampliCube is a qualitative in vitro test for the specific detection of DNA or RNA in human sample material. It uses specific primers and a probe for the real-time PCR amplification and detection of DNA or RNA. ampliCube test systems are characterized by high safety and reliability with maximum sensitivity and specificity.
MIKROGEN ampliCube advantages
Safe diagnosis
- High sensitivity and specificity
- High safety: internal control for monitoring nucleic acid extraction (RNA/DNA) and inhibition in each real-time PCR reaction
Flexible and compatible
- Compatible with most common real-time PCR cyclers
- Compatible with different RNA/DNA extraction methods
Technical data
Method | Real-time PCR technology |
Instruments | Validated and compatible with different real-time PCR cyclers, such as Roche LightCycler® 480 II, Qiagen Rotor-Gene® Q, Bio-Rad CFX96, Applied Biosystems QuantStudioTM 5, Mic Magnetic Induction Cycler |
Storage | -25°C to -18°C |
Available tests
The following tests are available:
Respiratory infections
- 50101 ampliCube Respiratory Bacterial Panel 1
- 50111 ampliCube Respiratory Bacterial Panel
- 50121 ampliCube Respiratory Bacterial Panel 3
- 50131 ampliCube Respiratory Bacterial Panel 4
- 50142 ampliCube Coronavirus Panel
- 50143 (50), 50144 (500) ampliCube Coronavirus SARS-CoV-2
- 50145 ampliCube SARS-CoV-2 Variants
- 50163 (50), 50164 (500) ampliCube Respiratory Flu & SARS-CoV-2
- 50173 (50), 50174 (500) ampliCube Respiratory Flu & SARS-CoV-2 LC
- 50102 ampliCube Respiratory Viral Panel 1
- 50112 ampliCube Respiratory Viral Panel 2
- 50122 ampliCube Respiratory Viral Panel 3
- 50132 ampliCube Respiratory Viral Panel 4
- 50152 ampliCube Respiratory Viral Panel 5
Gastrointestinal infections
- 50001 ampliCube Gastrointestinal Bacterial Panel 1
- 50011 ampliCube Gastrointestinal Bacterial Panel 2
- 50002 ampliCube Gastrointestinal Viral Panel 1
- 50012 ampliCube Gastrointestinal Viral Panel 2
Sexually transmitted diseases
- 50301 ampliCube STD Panel 1
- 50302 ampliCube STD Panel 2
- 50303 ampliCube STD Panel 3
Hepatitis E
- 55002 ampliCube HEV 2.0 Quant
Multi drug resistance
- 50401 ampliCube MDR Panel 1
- 50402 ampliCube MDR Panel 2
- 50403 ampliCube MDR Panel 3
- 50404 ampliCube MDR Panel 4
- 50405 ampliCube MDR Panel 5
- 50406 ampliCube MDR Panel 6
Additional reagents
- 50502 ampliCube Color Compensation Kit (5-Plex for Roche LightCycler® 480 II)
- 50503 ampliCube Color Compensation Kit (5-Plex for Roche cobas z 480 Analyzer)
- 50504 ampliCube Dye calibration kit for the Quant Studio 5 PCR cycler (5-Plex, is only necessary with 5-Plex PCR kits)
- 50505 ampliCube CFX 96 (BioRad) dye calibration
Marketing materials
MIKROGEN Molecular Diagnostics flyer (EN)
Video
More information
Visit website: Mikrogen Diagnostik - Product Navigator
alphaCube
alphaCube is a qualitative in vitro test for the specific detection of DNA or RNA in human sample material. It uses specific primers and a probe for the real-time PCR amplification and detection of DNA or RNA. alphaCube test systems are characterized by high safety and reliability with maximum sensitivity and specificity.
MIKROGEN alphaCube advantages
Easy handling
- Complete PCR kits with ready-to-use reagents
- Standard cycling program for all pathogens
Safe diagnosis
- High sensitivity and specificity
- High safety: internal control for monitoring nucleic acid (RNA/DNA) extraction and Inhibition in each real-time PCR reaction
Flexible and compatible
- Compatible with most common real-time PCR cyclers
- Compatible with different RNA/DNA extraction methods
Technical data
Method | Real-time PCR technology |
Instruments | Validated and compatible with different real-time PCR cyclers, such as Roche LightCycler® 480 II, Qiagen Rotor-Gene® Q, Bio-Rad CFX96, Applied Biosystems QuantStudioTM 5 Dx, Applied Biosystems ABI 7500, 7300, Mic Magnetic Induction Cycler |
Storage | ≤ -18°C |
Stability | Reagents can be stored at +2°C to +8°C for 6 months |
Available tests
The following tests are available:
Respiratory infections
- 830559 (96), 830560 (32) alphaCube Bordetella
- 830539 (96), 830540 (32) alphaCube Legionella
- 830535 (96), 830536 (32) alphaCube PanLegionella
- 830561 (96), 830562 (32) alphaCube MTB
- 830566 (96), 830567 (32) alphaCube MTB/NTM/MAC
- 830509 (96), 830510 (32) alphaCube Entero 2.0
- 830507 (96), 830508 (32) alphaCube respiraRNA 3.0
Gastrointestinal infections
- 830501 (96), 830502 (32) alphaCube gastroplexVirus
- 830503 (96), 830504 (32) alphaCube gastroplexVirus PLUS 2.0
- 830509 (96) ,830510 (32) alphaCube Entero 2.0
- 830513 (96) alphaCube Noro
Tick borne infections
- 830525 (96), 830526 (32) alphaCube Babesia
- 830527 (96), 830528 (32) alphaCube Borrelia
- 830576 (96), 830577 (32) alphaCube Borrelia/Rickettsia
- 830533 (96), 830534 (32) alphaCube Ehrlichia
- 830574 (96), 830575 (32) alphaCube Rickettsia
- 830519 (96), 830520 (32) alphaCube TBE
Tropical fever
- 830568 (96), 830569 (32) alphaCube TBE/WNV
- 830563 (96), 830564 (32) alphaCube Tropical Fever 1
Others
- 830547 (96), 830548 (32) alphaCube GBS
- 830572 (96), 830573 (32) alphaCube HSV/VZV
- 830557 (96), 830558 (32) alphaCube MRSA 3.0
- 830570 (96), 830571 (32) alphaCube PVL-MRSA
Additional reagents
- 831009 alphaCube LC480 Color Compensation
- 831032 alphaCube Color Compensation Kit RespiraRNA 3.0
Marketing materials
MIKROGEN Molecular Diagnostics flyer (EN)
More information
Visit website: Mikrogen Diagnostik - Product Navigator
T-Track® TB
T-Track® TB is a qualitative diagnostic test, suitable for screenings, to determine TB-specific reactivity of T-cells. Based on a patented technology, this RT-qPCR-based test is intended for use as an aid in the diagnosis of M. tuberculosis infection (including active disease). The T-Track® TB assay consists of two diagnostic kits:
- T-Track® TB Stimulation: Stimulation of TB-specific immune cells, via incubation with TB antigens, followed by stabilization of RNA.
- T-Track® TB Quant PCR: Measurement of the relative expression of specific classification markers via reverse transcription and quantitative PCR (RT-qPCR). Software based analysis.
Differential expression levels of the classification markers in stimulated and unstimulated blood samples may indicate an infection with M. tuberculosis. Results must be interpreted within the context of all relevant clinical and laboratory findings.
T-Track® TB: T-cell assay for improved diagnostics
- CE-marked IVD RT-qPCR product
- Aid in the diagnosis of M. tuberculosis infection (including active disease)
- Highly sensitive, patented technology: Including a marker also for the early phase of infection
- Measurement and analysis of the relative expression of the specific markers IFNG and CXCL10, after in vitro stimulation of immune cells with the TB antigens ESAT-6 und CFP-10
- Easy handling, standardized and semi-automated processing
- Software based analysis
Technical data
Method | RT-qPCR |
Sample materials | Whole blood (heparinized) |
Sensitivity | 94,81% |
Specificity | 94,03% |
Storage | T-Track® TB Stimulation at +2°C - 8°C, T-Track® TB Quant PCR at -25°C-15°C |
Available tests
The following tests are available:
- 11001004 T-Track® TB Stimulation
- 11001005 T-Track® TB Quant PCR
Marketing materials
MIKROGEN T- Track® TB flyer (EN)
More information
Visit website: Mikrogen - T-Track® TB Stimulation / Quant PCR